AC output specification: AC220V~50Hz
Model |
Input Voltage |
Rated Power |
Overload Power |
Peak Power |
1500W model |
48V/60V/72V |
1500W |
1850W |
3000W |
2000W model |
48V/60V/72V |
2000W |
2300W |
4000W |
3000W model |
48V/60V/72V |
3000W |
3200W |
6000W |
6000W model |
48V/60V/72V |
6000W |
6500W |
12000W |
The unit provides input reverse polarity protection, output short circuit protection, overload protection, over-temperature protection, under-voltage protection and over-voltage protection.
Display Code |
Protection |
Explanation |
LV |
Under-voltage protection |
Battery voltage falls below the minimum working voltage of the inverter |
OL |
Overload protection |
Load exceeds the rated power of the inverter |
OV |
Over-voltage protection |
Battery voltage rises above the maximum working voltage of the inverter |
OT |
Over-temperature protection |
Temperature exceeds the maximum the inverter can withstand |
— |
Short-circuit protection |
Load short circuit — the inverter stops output immediately |
Nominal Voltage |
Under-voltage Value |
Over-voltage Value |
48V |
39V |
62V |
60V |
49V |
78V |
72V |
59V |
94V |
Connection: battery → inverter → AC appliances. Typical loads include:
Misuse or incorrect connection may injure people or damage the inverter and connected equipment. Please read the following before use:
Warning — electric shock hazard, keep away from children: the AC output socket is the same as a household socket and can be lethal if misused. Do not insert foreign objects into the socket, fan or ventilation openings, and do not expose the unit to rain, snow, fog, oil or heavy dust.
Warning — ventilation: do not install the inverter in an enclosed space. Under high load, keep at least 5cm of clearance around the unit. Do not place heat-sensitive objects next to it while in use. The inverter can be stored for long periods at room temperature.
Warning — explosion risk: if smoke, unusual smell or abnormal noise occurs, disconnect the battery immediately and stop using the unit.
If the unit still does not work after the self-check steps above, contact your seller for technical guidance. To speed up diagnosis, please have the following ready: model / power rating, fault symptom, fault code shown on the display, and input battery voltage.
For pricing, OEM/ODM and bulk orders, please contact our sales team.
This content pack contains no photos — use your own product photography in the template modules:
Q: The inverter does not respond at all. What should I check?
A: Check that the battery and inverter are firmly connected and reconnect if necessary; charge the battery if it is flat; confirm the positive and negative polarity is correct; check that the battery voltage is not too low and clean the terminals with a dry cloth if contact is poor.
Q: The inverter has no output.
A: Battery voltage too low — recharge or replace the battery; load current too high — switch off part of the load and restart the inverter; over-temperature protection — let the unit cool down and move it to a ventilated place; failed start — restart the inverter; output terminal loose — reconnect the load.
Q: Why is the output power insufficient?
A: The connection cable may be too thin or poorly connected, so the current cannot reach its maximum; the battery capacity may be insufficient to supply the required current; the battery specification may not match the unit; for inductive loads, the back-EMF at startup can far exceed the rated power — in that case choose a larger inverter.
Q: Which battery voltages are supported?
A: 48V, 60V and 72V. Set the manual switch to match your battery before connecting. The under-voltage and over-voltage thresholds are 39V/62V for 48V, 49V/78V for 60V and 59V/94V for 72V.
Q: Can I connect it to the grid?
A: No. This inverter is designed for battery input only and must never be connected to the mains supply.