JYINS 5000W Pure Sine Wave Power Inverter
Product Introduction
The JYINS 5000W pure sine wave inverter is a heavy-duty industrial-grade power solution, delivering 5000W continuous rated power and 10000W peak surge power. Designed for medium-to-large commercial, industrial and off-grid power scenarios, it features pure sine wave output identical to grid power, supporting uninterrupted full-load operation for extended periods.
Equipped with a high-precision dual intelligent display system, full battery type compatibility and industrial-grade reinforced circuit design, this product provides stable, reliable and high-power power support for medium and large-scale power demand, and is the preferred choice for commercial backup, industrial operation and large off-grid energy storage systems.
Core Advantages
Heavy-duty Industrial Power Output
5000W continuous power supply, 10000W instantaneous peak capacity, stably drives heavy inductive loads such as industrial motors, large air conditioners and mechanical equipment, supporting long-term full-load operation without derating.
Dual-screen Intelligent Monitoring
High-definition LCD display + LED status indicator, real-time monitoring of input voltage, battery SOC, output power, load rate, operating temperature and fault codes, realizing visualized and intelligent power management.
Wide Voltage & Full Battery Compatibility
Automatically adapts to 12V/24V/48V DC input, fully compatible with gel batteries, lead-acid batteries, lithium iron phosphate batteries and ternary lithium batteries, with built-in battery-specific protection parameters.
96% Ultra-high Conversion Efficiency
Adopts advanced synchronous rectification and soft switching technology, conversion efficiency up to 96%, effectively reducing energy loss and heat generation, and improving overall system economy.
Scalable Parallel Expansion
Supports up to 4 units parallel connection, realizing 20000W total output power, flexibly meeting the power upgrade demand of different scenarios.
Industrial-grade Protection System
10-fold comprehensive protection: over-voltage, under-voltage, overload, over-temperature, short-circuit, reverse connection, over-current, lightning, surge and isolation protection, adapting to harsh industrial and outdoor environments.
About JYINS
Founded in 1993, JYINS Co., Ltd. is a national high-tech enterprise focusing on power inverter R&D and manufacturing for 30 years, located in Liushi Town, China's Electric Apparatus Capital. We have a professional R&D team of 50+ senior engineers, advanced automated production lines and complete quality testing systems.
All our products have passed ISO9001, CE, FCC, RoHS and IEC international certifications, with 47 national invention and utility model patents. Our products are exported to more than 80 countries and regions around the world, with cumulative shipments exceeding 11 million units, widely used in household, commercial, industrial and new energy fields.
Application Scenarios
1. Small Factory & Workshop Power Supply
Provides stable power for production equipment, electric tools, welding machines, cutting machines, lighting systems and office equipment in small processing plants, manufacturing workshops and maintenance facilities, ensuring uninterrupted production during power outages.
2. Medium & Large Commercial Backup Power
Suitable for shopping malls, hotels, restaurants, supermarkets and office buildings, powers central air conditioners, refrigeration equipment, lighting systems, elevators (low-power) and office equipment, avoiding business interruption and economic losses caused by grid failures.
3. Large Off-grid Photovoltaic Power Stations
Matches 5kW-20kW off-grid photovoltaic energy storage systems, suitable for rural areas, mountainous regions, islands and other areas without grid coverage, providing stable all-day power supply for households, villages and public facilities.
4. Communication Base Station & Infrastructure Power
Supports backup power for communication base stations, monitoring systems, road lighting and outdoor infrastructure, ensuring 24-hour uninterrupted operation of public facilities.
5. Large RV Camp & Outdoor Base Power
Provides full power support for large RV camps, outdoor activity bases, construction camps and scenic spots, powering air conditioners, kitchen equipment, lighting, entertainment facilities and public service equipment.
6. Agricultural & Breeding Facility Power
Powers ventilation equipment, water pumps, temperature control systems, feeding equipment and lighting systems for farms, greenhouses and aquaculture bases, ensuring stable operation of agricultural production facilities.
Frequently Asked Questions
Q1: What equipment can the 5000W inverter drive?
A: It can stably power 3HP air conditioners, electric water heaters, industrial water pumps, small motors, welding machines, various electric tools, large refrigeration equipment and all conventional commercial and household electrical appliances. It supports simultaneous operation of multiple devices as long as the total continuous power does not exceed 5000W.
Q2: What battery configuration is recommended for 5000W inverters?
A: It is recommended to use 24V 300Ah+ or 48V 200Ah+ battery packs. Taking 48V 200Ah lithium battery as an example, it can run for about 1.8 hours under full 5000W load, and 3.5-4 hours under 50% load. The battery capacity can be flexibly configured according to the required runtime.
Q3: What are the wiring requirements for installation?
A: For 48V input, it is recommended to use 10mm² or above copper cables; for 24V input, 16mm² or above copper cables are recommended. The shorter the cable length, the better, to reduce line loss. We provide detailed wiring diagrams and installation guidelines, and professional electricians are recommended for installation in industrial scenarios.
Q4: How many units can be connected in parallel? What is the maximum total power?
A: This product supports up to 4 units connected in parallel, with a maximum total output power of 20000W. We provide dedicated parallel busbars and cables, and the parallel system supports synchronous output and unified monitoring, which can be flexibly expanded according to power demand.
Q5: How is the heat dissipation performance for long-term full-load operation?
A: It adopts an industrial-grade intelligent temperature control heat dissipation system, equipped with 4 high-volume silent fans and an all-aluminum fin heat sink. The fan speed is automatically adjusted according to the load and temperature, supporting 24/7 continuous full-load operation, with the operating temperature controlled within the safe range.
Q6: What is the warranty and after-sales service?
A: We provide a 5-year global warranty for the whole machine and lifetime technical support. For non-human quality problems, free replacement is provided within 6 months, and free maintenance is provided within 5 years. We have local after-sales service centers and warehouses in Europe, North America, Southeast Asia and the Middle East, providing fast after-sales response and on-site service support.
Product Description
| Model |
5000W-12V |
5000W-24V |
5000W-48V |
| Output Power |
5000W |
| Peak Power |
10000W |
| DC Input Voltage Range |
DC12V(9.5V-15.5V) |
DC24V(19V-31V) |
DC48V(38V-62V) |
| AC Output Voltage (Single Choice) |
100V/110V/120V/220V/230V/240V |
| Unload Current |
≤0.9A |
≤0.5A |
≤0.35A |
| Output Frequency |
(50Hz±2Hz) or( 60Hz±2Hz) |
| Output Waveform |
Modified sine wave |
| Display |
LED or LCD display |
| USB Output Votlage / Current |
5V 2A (Support QC3.0 fast charge up to 18W) |
| Max. Output Efficiency |
88% |
90% |
92% |
| Low Voltage Protection |
Alarm “Bi” with 2s interval +red and green lights flashing alternately / restart automatically when voltage recover |
| Over Voltage Protection |
Alarm “BiBi” with 1s interval +red and green lights flashing alternately / restart automatically when voltage recover |
| Over Load Protection |
Alarm “Bi” continously +red light flashing / restart automatically when load power recover; If it is closed after twice recover, it need restart manually. |
| Over Temp Protection |
Alarm “BiBiBi” with 1s interval +red and green lights flashing alternately / restart when temp recover |
| Short Circuit Protection |
yes |
| DC Reverse Connection Protection |
Fuse burnt |
| Low Voltage Alarm Range |
10.5v±0.5v |
21v±0.5v |
42v±0.5v |
| Low Voltage Protection Range |
9.5v±0.5v |
19v±0.5v |
38v±0.5v |
| Low Voltage Recover Range |
12v±0.5v |
23v±0.5v |
46v±0.5v |
| Over Voltage Protection Range |
15.5v±0.5v |
31v±0.5v |
62v±0.5v |
| Over Voltage Recover Range |
14v±0.5v |
28v±0.5v |
56v±0.5v |
| Working Temperature |
-10℃~50℃ |
| Cooling Method |
Fan cooling (Temperature control) |
|