| Formam | Recuperatio tensionis intrantis AC | recuperatio tensionis intrantis infimae | recuperatio tensionis intrantis exsuperantis | Tensio exiens | ammplitudo frequentialis tensionis intrantis | currentis Output Aestimatus |
| 600A | 90–310 V | 110V | 290V | 230V | 43–57 Hz | 2.7A |
| 800A | 90–310 V | 110V | 290V | 230V | 43–57 Hz | 3.1A |
| 1000A | 90–310 V | 110V | 290V | 230V | 43–57 Hz | 5A |
| 2000 A | 90–310 V | 110V | 290V | 230V | 43–57 Hz | 8.8A |
| 3000 A | 90–310 V | 110V | 290V | 230V | 43–57 Hz | 12,2 A |
Scēnāriōs applicātiōnis stabilizātōris voltāgis

inverter āctūs cum stabilizātōre voltāgis
1. Apparātūs elēctricī domēsticī et domī
2. Officinae industriāles et māchinae praecīsae
3. Apparātūs lāser et ferrāmenta māchināria CNC
4. Hospitālia et instrumenta medica praecīsa
5. Officia, fora, hōtēlia et aedificia commericialia
6. Centra datōrum, cēntrum servōrum et stationēs bāsis commūnicātiōnis
7. Laboratōria scholārium et institūta rērum investigāndārum
8. Instituta bancaria, viaria et publicae securitatis
9. Loca aedificiorum et potestas ad usus temporarios
10. Regiones rurales et veteres communitates cum voltatione instabili
Regulator electronicus voltationis AC praecellentem habet structuram, stabilem operationem, fidam qualitatem, latum ambitum voltationis intrantis et facilem usum, ideoque in mercatus domesticos ac externos maxime probatur, praesertim in regionibus Europaeis. Omnes utentes ad usum nostrorum productorum invitantur.
pelagus euismod :
LCD crystallorum liquidorum parametrorum indicatio + LED lucis indicatio: Ingressus: Tensio ingressus; Egressus: Tensio egressus; Potentia egressus: Potentia operativa. Status operativus viridi lucerna indicatur, dum status defectus lucerna defectus indicat. Si temperatura anormalis, supercarrus, curtus circuitus, supervoltatio aut subvoltatio accidant, lucerna correspondens accenditur.
Descriptio LED indicis: Viridis lucerna statum operativum indicat; rubra lucerna supercarrum TRB indicat; rubra lucerna insufficientem tensionem AC/UNDV indicat; rubra lucerna excessivam tensionem AC/OUV indicat.
Protectio contra curtum circuitum: Cum curtus circuitus in egressu accidit, egressus interrumpitur et post resolutionem curti circuitus automato ad normam redit.
Functio protectionis contra altam temperaturam: Cum temperatus radiantis supra 80 °°C + 2 °°C ascendit, egressus automato interrumpitur; cum temperatus infra 60° C decidit °°C + 2 °C, functio producti ad normam revertitur.
Ventilator Intellegens: Ventilator automaticus incipit cum temperatus radiatori superat 60 °C et desinit cum cadit infra 40 °C.
protectio Superōnus :
2. Intrantis supervacuitas. Cum tensio intrans est 185 V, currentis intrans excedit nominalem currentem intrantem, quod causat decrementum tensionis producti. Productio disjungetur cum tensio cadit ad 180 V ± 5 V et post 13 secunda reinitiabitur.
3. Cum currentis producti excedit 200% nominis currentis, systema statim protectionem activat, productum disjungit, et post 13 secunda reinitiat.
4. Cum currentis producti excedit 200% nominis currentis, systema statim protectionem initiabit.
Productum disjungere et post 13 secunda reinitiare.
Haec functio applicabilis est cum tensio intrans inter 190 V et 240 V variat.
Cum intensitas currentis exeuntis superat 150 % intensitatis currentis exeuntis nominis, tensio exeuntis minuitur; cum tensio cadit infra 180 V ± 5 V, intratio et exitus in statu directae transductionis sunt.
Cum intensitas currentis exeuntis ad 80 % intensitatis currentis nominis decrescit, systema se ipsum reponit et tensionem exeuntis stabilizat.
Instructiones de installatione: Dum machina operatur, ea a substantiis inflammabilibus et explosivis, altis temperaturis, humiditate, aliisque condicionibus asperis remota esse debet. In loco bene ventilato, arido, absque sole directo collocanda est.
|
formam |
Recuperatio tensionis intrantis AC |
Applica humilem recuperationem tensionis |
Recuperatio supra-tensionis intrantis |
O tensio exeuntis |
Latitudo frequentialis tensionis intrantis |
R expulsus est- inserere curren-tem |
Evaluatus Input Correntia |
Ventilator Intellegens |
Tensio inpūta maior est quam 190 V |
Tensio inpūta minor est quam 185 V |
|
JYVS600 |
90–310 V |
110V |
290V |
230V |
43–57 Hz |
2.7A |
3.1A |
N o |
620W |
W = V × 2,88 |
|
JYVS800 |
90–310 V |
110V |
290V |
230V |
43–57 Hz |
3.1A |
3,9 A |
N o |
720W |
W = V × 3,65 |
|
JYVS1000 |
90–310 V |
110V |
290V |
230V |
43–57 Hz |
5A |
9.2A |
N o |
1000W |
1000W |
|
JYVS2000 |
90–310 V |
110V |
290V |
230V |
43–57 Hz |
8.8A |
10,5 A |
Ita |
2000W |
W = V × 9,76 |
|
JYVS3000 |
90–310 V |
110V |
290V |
230V |
43–57 Hz |
12,2 A |
14A |
Ita |
3000W |
W = V × 13 |
Formula ad potestatem exirentem computandam, cum voltatio intrans minor est quam 185 V:
Si voltatio intrans modello AC-88A est 170 V, maxima potestas exirens est
P = 170 × 3,65 = 620,5 W
1. **Quid est stabilizator electronicus tensionis?**
Est instrumentum quod automaticē fluctuantem tensionem intrantem in constantem tensionem normalem extrantem stabilizat, ut apparatus electrici protegantur.
2. **Quam ambitum tensionis sustinet?**
Communis intratio: 140 V–260 V; norma extratio: AC 220 V/110 V.
3. **Ad quae instrumenta id aptum est?**
Ad aerem frigidarium, refrigeratorem, computatrum, impressoram, instrumentum medicinale, parva instrumenta industrialia, apparatus domesticos electricos, etc.
4. **Quae sunt eius praecipua commoda?**
Cito respondet, parvum est, silentium facit, altam habet praecisionem, plene automaticum est, diuturnam habet vitam.
5. **Quomodo idoneum modello potestatis eligere debemus?**
Recommendantur 1,5–2 vicibus potestas oneris realis ad evitandam damna ob supraonerationem.
6. **Num cotidiana cura opus est?**
Serva ventilationem siccum, vitato pulveris accumulo et gravissimo onere in usu diuturno; nulla cura complexa opus est.
7. **Cur lucerna indicativa micat?**
Maxime causatur a fluctuatione valde extrema voltatis, onere nimio, aut connexione conductuum impari.
8. **Num continue viginti quattuor horas operari potest?**
Ita, typi industriales et domestici operationem diuturnam continuam stabilemque sustentant.
9. **Quae functiones protectionis habet?**
Protectio automatica contra voltatum nimium, voltatum parvum, onus nimium, calorem nimium, et circuitum breve.
10. **Num installatio difficilis est?**
Designatio simplicis connexionis, insertio directa vel fixatio per conductus, facile ad instaurandum et utendum.